Experimental Medical Physics
print


Breadcrumb Navigation


Content

2013

Peer-reviewed journals:

Medical Physics

  1. W. Assmann, R. Becker, H. Otto, M. Bader, L. Clemente, S. Reinhardt, C. Schäfer, J. Schirra, S. Uschold, A. Welzmüller, R. Sroka, 32P-haltige Folien als Implantate für die LDR-Brachytherapie gutartiger Stenosen in der Urologie, Zeitschrift für Medizinische Physik 23, 21-32 (2013).
  2. S. Reinhardt, W. Draxinger, J. Schreiber, W. Assmann, A pixel detector system for laser-accelerated ion detection, Journal of Instrumentation 8, P03008 (2013).
  3. Robert C, Dedes G, Battistoni G, Böhlen TT, Buvat I, Cerutti F, Chin MP, Ferrari A, Gueth P, Kurz C, Lestand L, Mairani A, Montarou G, Nicolini R, Ortega PG, Parodi K, Prezado Y, Sala PR, Sarrut D, Testa E., Distributions of secondary particles in proton and carbon-ion therapy: a comparison between GATE/Geant4 and FLUKA Monte Carlo codes, Phys Med Biol. 2013 May 7;58(9):2879-99. doi: 10.1088/0031-9155/58/9/2879. Epub 2013 Apr 10. PMID: 23571094 [PubMed - in process]

  4. A. Mairani, TT Böhlen, A Schiavi A, Tessonnier T, Molinelli S, Brons S, Battistoni G, Parodi K, Patera V., A Monte Carlo-based treatment planning tool for proton therapy, Phys Med Biol. 2013 Apr 21;58(8):2471-90. doi: 10.1088/0031-9155/58/8/2471. Epub 2013 Mar 21, PMID: 23514837 [PubMed - in process].

  5. D. Habermehl, Debus J, Ganten T, Ganten MK, Bauer J, Brecht IC, Brons S, Haberer T, Haertig M, Jaekel O, Parodi K, Welzel T, Combs SE., Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma - feasibility and clinical response, Radiat Oncol. 2013 Mar 13;8(1):59. [Epub ahead of print], PMID: 23497349 [PubMed - as supplied by publisher] Free Article.

  6. I. Rinaldi, Brons S, Gordon J, Panse R, Voss B, Jäkel O, Parodi K, Experimental characterization of a prototype detector system for carbon ion radiography and tomography, Phys Med Biol. 2013 Feb 7;58(3):413-27. doi: 10.1088/0031-9155/58/3/413. Epub 2013 Jan 8., PMID: 23296259 [PubMed - in process].

  7. D. Sánchez-Parcerisa, Gemmel A, Jäkel O, Rietzel E, Parodi K, Influence of the delta ray production threshold on water-to-air stopping power ratio calculations for carbon ion beam radiotherapy, Phys Med Biol. 2013 Jan 7;58(1):145-58. doi: 10.1088/0031-9155/58/1/145. Epub 2012 Dec 10, PMID: 23221148 [PubMed - in process].

  8. K. Parodi, A. Mairani, F. Sommerer, Monte Carlo-based parametization of the lateral dose spread for clinical treatment planning of scanned proton and carbon ion beams, J Radiat Res. 2013 Jul. 54 Suppl 1:i91-i96. doi: 10.1093/jrr/rrt051.
  9. TT. Böhlen, J. Bauer, M. Dosanjih, A. Ferrari, T. Haberer, K. Parodi, V. Patera, A. Mairani, A Monte Carlo-based treatment-planning tool for ion beam therapy, J Radiat Res. 2013 Jul, 54 Suppl 1:i77-i81. doi: 10.1093/jrr/rrt050.
  10. J. Bauer, D. Unholtz, C. Kurz, K. Parodi, An experimental approach to improve the Monte Carlo modelling of offline PET/CT-imaging of positron emitters induced by scanned proton beams, Phys Med Biol. 2013 Aug 7;58(15):5193-213. doi: 10.1088/0031-9155/58/15/5193. Epub 2013 Jul 9, PMID: 23835872   [PubMed - in process]
  11. SE Combs, M. Djosanjh M, R. Pötter, R. Orrechia, T. Haberer, M. Durante, P. Fossati, K. Parodi, J.Balosso, U. Amaldi, M. Baumann, J. Debus, Towards clinical evidence in particle therapy: ENLIGHT, PARTNER, ULICE and beyond, J Radiat Res. 2013 Jul, 54 Suppl 1:i6-i12. doi: 10.1093/jrr/rrt039. No abstract available, PMID:  23824128, [PubMed - in process]
  12. D. Sánchez-Parcerisa, A. Gemmel, K. Parodi, E. Rietzel, A 3D model to calculate water-to-air stopping power ratio in therapeutic carbon ion fields, J Radiat Res. 2013 Jul; 54 Suppl 1:i143-i146. doi: 10.1093/jrr/rrt035. No abstract available, PMID: 23824119, [PubMed - in process]
  13. K. Stützer, C. Bert, W. Enghardt, S. Helmbrecht, K. Parodi, M. Priegnitz, N. Saito, F. Fiedler, Experimental verification of a 4D MLEM reconstruction algorithm used for in-beam PET measurements in particle therapy, Phys Med Biol. 2013 Aug 7; 58(15):5085-111. doi: 10.1088/0031-9155/58/15/5085. Epub 2013 Jul 8. PMID: 23831685 [PubMed - in process]
  14. G. Landry, K. Parodi, JE Wildberger, F. Verhaegen. Deriving concentrations of oxygen and carbon in human tissues using single- and dual-energy CT for ion therapy applications, Phys Med Biol. 2013 Aug 7; 58(15):5029-48. doi: 10.1088/0031-9155/58/15/5029. Epub 2013 Jul 8. PMID:    23831541 [PubMed - in process]
  15. A. Ruciński, J. Bauer, P. Campbell, S. Brons, D. Unholtz, G. Habl, K. Herfarth, J. Debus, C. Bert, K. Parodi, O. Jäkel, T. Haberer, Preclinical investigations towards the first spacer gel application in prostate cancer treatment during particle therapy at HIT, Radiat Oncol. 2013 Jun 6; 8:134. doi: 10.1186/1748-717X-8-134, PMID: 23742233 [PubMed - in process]
  16. S. Molinelli, A. Mairani, A. Mirandola, G. Vilches Freixas, T. Tessonnier, S. Giordanengo, K. Parodi, M. Ciocca, R. Orecchia, Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the involved uncertainties, Phys Med Biol. 2013 Jun 7; 58(11):3837-47. doi: 10.1088/0031-9155/58/11/3837. Epub 2013 May 16, PMID: 23681116, [PubMed - in process]
  17. J. Bauer, D. Unholtz, F. Sommerer, C. Kurz, T. Haberer, K. Herfarth, T. Welzel, SE Combs, J. Debus, K. Parodi, Implementation and initial clinical experience of offline PET/CT-based verification of scanned carbon ion treatmentRadiother Oncol. 2013 May; 107(2):218-26. doi: 10.1016/j.radonc.2013.02.018. Epub 2013 May 4, PMID: 23647759 [PubMed - in process]
  18. S. Helmbrecht, W. Enghardt, K. Parodi, B. Didinger, J. Debus, D. Kunath, M. Priegnitz, F. Fiedler, Analysis of metabolic washout of positron emitters produced during carbon ion head and neck radiotherapy, Med Phys. 2013 Sep;40(9):091918. PMID: 24007169.

Nuclear Physics

  1. C. Weber, R. Meißner, P. Müller, P.G. Thirolf, Recent developments at MLLTRAP: Improving the system for mass measurements and in-trap observation of nuclear decays, Nucl. Instr. Meth. B 317 (2013) 532.
  2. E. Minaya Ramirez, D. Ackermann, K. Blaum, M. Block, C. Droese, Ch.E. Düllmann, M. Eibach, S. Eliseev, E. Haettner, F. Herfurth, F.P. Heßberger, S. Hofmann, G. Marx, D. Nesterenko, Yu.N. Novikov, W.R. Plaß, D. Rodriguez, C. Scheidenberger, L. Schweikhard, P.G. Thirolf, C. Weber,
    Recent developments for high-precision mass measurements of the heaviest elements at SHIPTRAP,
    Nucl. Instr. Meth.  B 317 (2013) 501.

  3. B. Blank, S. Grévy, P.G. Thirolf, and C. Weber,
    Perspectives for mass spectrometry at the DESIR facility of SPIRAL2,
    International Journal of Mass Spectrometry 349–350, 264–269 (2013).
  4. C. Weber, P. Müller, P.G. Thirolf,
    Developments in Penning trap (mass) spectrometry at MLLTRAP: Towards in-trap decay spectroscopy,
    International Journal of Mass Spectrometry 349–350, 270–276 (2013)
  5. C. Droese, D. Ackermann, L.-L. Andersson, K. Blaum, M. Block, M. Dworschak, M. Eibach, S. Eliseev, U. Forsberg, E. Haettner, F. Herfurth, F.P. Hess berger, S. Hofmann, J. Ketelaer, G. Marx, E. Minaya Ramirez, D. Nesterenko, Yu. Novikov, W.R. Plass , D. Rodriguez, D. Rudolph, C. Scheidenberger, L. Schweikhard, S. Stolze, P.G. Thirolf, C. Weber, High precision mass measurements of 203-207Rn and 213Ra with SHIPTRAP, Eur. Phys. Jour. A 49 (2013) 13.
  6. L. Csige, D.M. Filipescu, J. Gulyas, M. Günther, D. Habs, H.J. Karwowski, A. Krasznahorkay, G.C. Rich, P.G. Thirolf, Photofission of 238U induced by a quasi-monochromatic, Compton-backscattered gamma-beam, Acta Phys. Pol. B 44, 643 (2013).

  7. P.G. Thirolf, L. v.d. Wense, D. Kalb, M. Laatiaoui, Towards an all-optical access to the lowest nuclear excitation in 229mTh, Acta Phys. Pol. B 44, 391 (2013).

  8. L. v.d. Wense, P.G. Thirolf, D. Kalb, M. Laatiaoui, Towards a direct transition energy measurement of the lowest nuclear excitation in 229mTh, Journal of Instrumentation 8, P03005 (2013).

  9. N. Warr, J. Van de Walle, M. Albers, F. Ames, B. Bastin, C. Bauer, V. Bildstein, A. Blazhev, S. Bönig, N. Bree, B. Bruyneel, P. Butler, J. Cederkäll, E. Clement, T.E. Cocolios, T. Davinson, H. De Witte, P. Delahaye, D.D. Di Julio, J. Diriken, J. Eberth, A. Ekström, J. Elseviers, S. Emhofer, D.V. Fedorov, V.N. Fedosseev, S. Franchoo, C. Fransen, L. Gaffney, J. Gerl, R. Gernhäuser, T. Grahn, D. Habs, H. Hess, A. Hurst, M. Huyse,
    S. Ilieva, O. Ivanov, J. Iwanicki, D. Jenkins, J. Jolie, N. Kesteloot, O. Kester, U. Köster, T. Kröll, R. Krücken, M. Lauer, J. Leske, K.P. Lieb, R. Lutter, L. Maier, B.A. Marsh, D. Mücher, M. Münch, O. Niedermaier, J. Pakarinen, M. Pantea, G. Pascovici, N. Patronis, D. Pauwels, A. Petts, N. Pietralla,
    R. Raabe, E. Rapisarda, P. Reiter, A. Richter, O. Schaile, M. Scheck, H. Scheit, G. Schrieder, D. Schwalm, M. Seidlitz, M. Seliverstov, T. Sieber, H. Simon, K.-H. Speidel, C. Stahl, I. Stefanescu, P.G. Thirolf, H.-G. Thomas, M. Thürauf, P. Van Duppen, D. Voulot, R. Wadsworth, G. Walter, D. Weißhaar, F. Wenander, A. Wiens, K. Wimmer, B.H. Wolf, P.J. Woods, K. Wrosek-Lipska, K.O. Zell,
    The Miniball setup at REX-ISOLDE, Eur. Phys. Journ. A 49 (2013)
  10. T. Kotthaus, P. Reiter, H. Hess, M. Kalkühler, A. Wendt, A. Wiens, R. Hertenberger, T. Morgan, P.G. Thirolf, H.-F. Wirth, T. Faestermann, Excited states of the odd-odd nucleus 230Pa, Phys. Rev. C 87, 044322 (2013).
  11. L. Csige, D.M. Filipescu, M.W. Ahmed, J. Gulyas, M.M. Günther, D. Habs, H.J. Karwowski, A. Krasznahorkay, G.C. Rich, L. Stroe, O. Tesileanu, P.G. Thirolf, Exploring the multi-humped fission barrier of 238U via sub-barrier photofission, Phys. Rev. C 87, 044321 (2013).
  12. A.I. Levon, G. Graw, R. Hertenberger, S. Pascu, P.G. Thirolf, H.-F. Wirth, P. Alexa, 0+ states and collective bands in 228Th by the (p,t) reaction, Phys. Rev. C 88, 014310 (2013).
  13. T. Kotthaus, P. Reiter, B. Bruyneel, M. Chatzistamatiou, J. Eberth, G. Gersch, H. Hess, I. Stefanescu, N. Warr, D. Weisshaar, A. Wiens, T. Morgan, R. Lutter, W. Schwerdtfeger, P.G. Thirolf, P. Bringel, H. Hübel, A. Neusser, Spectroscopy of excited states in 234U and search for a two-phonon state in 234U, Phys. Rev. C 88, 064306 (2013).
  14. D. Jordan, A. Algora, J.L. Taín, B. Rubio, J. Agramunt, A.B. Perez-Cerdan, F. Molina, L. Caballero, E. Nácher, A. Krasznahorkay, M.D. Hunyadi, J. Gulyás, A. Vitéz, M. Csatlós, L. Csige, J. Äystö, H. Penttilä, I.D. Moore,
    T. Eronen, A. Jokinen, A. Nieminen, J. Hakala, P. Karvonen, A. Kankainen, A. Saastamoinen, J. Rissanen,
    T. Kessler, C. Weber, J. Ronkainen, S. Rahaman, V. Elomaa, U. Hager, S. Rinta-Antila, T. Sonoda,
    K. Burkard, W. Hüller, L. Batist, W. Gelletly, A.L. Nichols, T. Yoshida, A.A. Sonzogni, K. Peräjärvi, A. Petrovici, K.W. Schmid, and A. Faessler, Total absorption study of the β decay of 102,104,105Tc, Phys. Rev. C 87, 044318 (2013). DOI: 10.1103/PhysRevC.87.044318

 Laser-Ion-Acceleration

Laser-driven ion acceleration from relativistically transparent nanotargets

B. M. Hegelich, I. Pomerantz, L. Yin, H. Wu, D. Jung, B. Albright, D. C. Gautier, S. Letzring, S. Palaniyappan, R. C. Shah, K. Allinger, R. Hörlein, J. Schreiber, D. Habs, J. Blakeney, G. Dyer, L. Fuller, E. Gaul, E. Mccary, A. R. Meadows, C. Wang, T. Ditmire, and J. C. Fernández
New Journal of Physics 15, 085015 (2013)

Laser-driven 1GeV carbon ions from preheated diamond targets in the break-out afterburner regime

D. Jung, L. Yin, D. C. Gautier, H. Wu, S. Letzring, B. Dromey, R. C. Shah, S. Palaniyappan, T. Shimada, R. Johnson, J. Schreiber, D. Habs, J. C. Fernández, B. M. Hegelich, and B. Albright
Physics of Plasmas 20, 083103 (2013) 

On the small divergence of laser-driven ion beams from nanometer thick foils

J. Bin, W. Ma, K. Allinger, H. Wang, D. Kiefer, S. Reinhardt, P. Hilz, K. Khrennikov, S. Karsch, X. Q. Yan, F. Krausz, T. Tajima, D. Habs, and J. Schreiber
Physics of Plasmas 20, 073113 (2013)

Relativistic electron mirrors from nanoscale foils for coherent frequency upshift to the extreme ultraviolet

D. Kiefer, M. Yeung, T. Dzelzainis, P. Foster, S. Rykovanov, C. L. Lewis, R. S. Marjoribanks, H. Ruhl, D. Habs, J. Schreiber, M. Zepf, and B. Dromey
Nature Communications 4, 1763 (2013)

A pixel detector system for laser-accelerated ion detection

S. Reinhardt, W. Draxinge, J. Schreiber, and W. Assmann
Journal of Instrumentation 8, P03008 (2013)

Efficient carbon ion beam generation from laser-driven volume acceleration

D. Jung, L. Yin, B. Albright, D. C. Gautier, S. Letzring, B. Dromey, M. Yeung, R. Hörlein, R. C. Shah, S. Palaniyappan, K. Allinger, J. Schreiber, K. Bowers, H. Wu, J. C. Fernández, D. Habs, and B. M. Hegelich
New Journal of Physics 15, 023007 (2013)

Stable laser-ion acceleration in the light sail regime

S. Steinke, P. Hilz, M. Schnürer, G. Priebe, J. Bränzel, F. Abicht, D. Kiefer, C. Kreuzer, T. Ostermayr, J. Schreiber, A. A. Andreev, T. P. Yu, A. Pukhov, and W. Sandner
Physical Review Special Topics - Accelerators and Beams 16, 011303 (2013)

Efficient and stable proton acceleration by irradiating a two-layer target with a linearly polarized laser pulse

H. Wang, X. Q. Yan, J. E. Chen, X.T. He, W. Ma, J. Bin, J. Schreiber, T. Tajima, and D. Habs
Physics of Plasmas 20, 013101 (2013)

Coherent synchrotron emission in transmission from ultrathin relativistic laser plasmas

B. Dromey, S. Cousens, S. Rykovanov, M. Yeung, D. Jung, D. C. Gautier, T. Dzelzainis, D. Kiefer, S. Palaniyappan, R. C. Shah, J. Schreiber, J. C. Fernández, C. L. Lewis, M. Zepf, and B. M. Hegelich
New Journal of Physics 15, 015025 (2013)

 Abstracts and Proceedings:

Medical Physics

  1. Krimmer J, Balleyguier L, Baudot J, Brons S, Caponetto L, Chabot M, Chen X, Dahoumane M, Dauvergne D, De Rydt M, Dedes G. Real-time online monitoring of the ion range by means of prompt secondary radiations. InAdvancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2013 3rd International Conference on 2013 Jun 23 (pp. 1-8). IEEE.
  2. S. Reinhardt, M. Hillbrand, J.J. Wilkens, W. Assmann, Evaluation of EBT3 films for use in clinical photon and proton beams, Radiotherapy and  Oncology 106,  s2,  (2013),  S288
  3. S. Kantz, S. Reinhardt, J. Hoppmann, M. Söhn, A. Kakoschke, H. Weingandt, W. Assmann, K. Parodi, C. Belka, M. Reiner, Investigation of the optimal design of IMRT QA tests with regard to the properties of the MLC and the measurement device,  Radiotherapy and Oncology 106, s2, (2013), S217.
  4. P.G. Thirolf, S. Aldawood, C. Lang, K. Parodi, Development of a Compton Camera for Online Range Monitoring
    of Laser-Accelerated Proton Beams, Med. Phys. 40, 144 (2013).
  5. K. Parodi, J. Polf, H. Paganetti and R. Schulte, New Technologies Addressing the Range Uncertainty of Proton Therapy, Med. Phys. 40 , 468 (2013).
  6. S. Reinhardt, M. Hillbrand, J. Wilkens, W. Assmann and K. Parodi, Evaluation of EBT2 and EBT3 Films for Dosimetry in Laser-Driven Ion Accelerators, Med. Phys. 40, 215 (2013).
  7. J. Bauer, M. Hildebrandt, D. Unholtz, C. Kurz and K. Parodi, On the Modelling of Facility-Specific PET Imaging for Proton Treatment Verification: Experimental Validation and Inter-Facility Comparison , Med. Phys. 40, 548 (2013).
  8. K. Frey, J. Bauer, D. Unholtz, C. Kurz, M. Kraemer, T. Bortfeld and K. Parodi,  TPSPET- A TPS-Based Approach for In-Vivo Dose Verification with PET in Proton Therapy , Med. Phys. 40, 547 (2013).
  9. K. Parodi, J. Bauer, C. Kurz, D. Unholtz, F. Sommerer, K. Frey, T. Haberer, K. Herfarth, T. Welzel, S. Combs and J. Debus, Offline PET/CT Imaging of Scanned Proton and Carbon Ion Beams: Initial Clinical Experience for Different Tumour Sites , Med. Phys. 40, 504 (2013).
  10. J. Schwaab, C. Sarti, M. Prall, R. Kaderka, C. Bert, C. Kurz, K. Parodi, M. Günther, J. Jenne, Ultrasound tracking for intra-fractional motion compensation in radiation therapy , 44. Jahrestagung der Deutschen Gesellschaft für Medizinische Physik,  Abstractband ISBN 978-3-9816002-1-6, p175 - 6 (2013).
  11. P. Thirolf, C. Lang, S. Aldawood, H. van der Kolff, J. Bortfeldt, L. Maier, D. R. Schaart, K. Parodi, Development of a Compton camera for online range monitoring of laser accelerated proton beams, 44. Jahrestagung der Deutschen Gesellschaft für Medizinische Physik, Abstractband ISBN 978-3-9816002-1-6, p281-2 (2013).
  12. K. Frey, D. Unholtz, J. Bauer, C.H. Min, T. Bortfeld, H. Paganetti, K. Parodi, Most-likely-shift method using an automated range analysis and uncertainty monitoring for PET-based in-vivo treatment verification in particle therapy, 44. Jahrestagung der Deutschen Gesellschaft für Medizinische Physik,  Abstractband ISBN 978-3-9816002-1-6, p284-5 (2013).
  13. F. Englbrecht, S. Reinhardt, A. Kakoschke, M. Hillbrand, M. Weick, G. Datzmann, J. Hauffe, K. Parodi,   Monte-Carlo modelling to support quality assurance at a clinical proton therapy facility, Abstractband ISBN 978-3-9816002-1-6, p721-2 (2013).
  14. C. Kurz, J. Bauer, L. Guerin, M. Conti, L. Eriksson and K. Parodi, Investigating the Limits of PET/CT Imaging at Very Low True Count Rates in Ion-Beam Therapy Monitoring, Conference Records IEEE NSS-MIC 2013, Seoul, M07-3 (2013).
  15. C. Kurz, J. Bauer, D. Unholtz, C. Gianoli, S. E. Combs, J. Debus, D. Richter, R. Kaderka, C. Bert, K. Stuetzer, G. Baroni and K. Parodi, Current Status of 4D Offline PET-Based Treatment Verification at the Heidelberg Ion-Beam Therapy Center, Conference Records IEEE NSS-MIC 2013, Seoul, M21-12 (2013).
  16. P.G. Thirolf, C. Lang, S. Aldawood, D. Habs, L. Maier, K. Parodi, Development of a Compton Camera for online monitoring and dosimetry of laser-accelerated proton beams,
    Verhandl. DPG (VI) 48, HK 69.3 (2013)
  17. S. Aldawood, C. Lang, D. Habs, L. Maier, K. Parodi, P.G. Thirolf, Characterization of a LaBr3 crystal with multi-anode PMT readout, Verhandl. DPG (VI) 48, HK 52.7 (2013).

 Nuclear Physics

  1. M. Block, D. Ackermann, K. Blaum, C. Droese, Ch.E. Düllmann, M. Eibach, S. Eliseev, E. Haettner, F. Herfurth, F.P. Heßberger, S. Hofmann, G. Marx, E. Minaya Ramirez, D. Nesterenko, Yu.N. Novikov, W.R. Plaß, D. Rodríguez, C. Scheidenberger, L. Schweikhard, P.G. Thirolf, C. Weber, Extending Penning trap mass measurements with SHIPTRAP to the heaviest elements, AIP Conf. Proc. 1521, 191-199 (2013).
  2. A.-A. Zakari-Issoufou, A. Porta, M. Fallot, A. Algora, J.L. Tain, E. Valencia, S. Rice, J. Agramunt, J. Äystö,
    M. Bowry, V.M. Bui, R. Caballero-Folch, D. Cano-Ott, V. Elomaa, E. Estévez, G.F. Farrelly, A. Garcia,
    W. Gelletly, M.B. Gomez-Hornillos, V. Gorlychev, J. Hakala, A. Jokinen, M.D. Jordan, A. Kankainen,
    F.G. Kondev, T. Martinez, E. Mendoza, F. Molina, I. Moore, A. Perez, Zs. Podolyak, H. Penttilä, P.H. Regan, J. Rissanen, B. Rubio, C. Weber, and IGISOL people, Measurement of fission products beta decay properties using a total absorption spectrometer, Fission 2013 – 5th Int. Workshop on Nuclear Fission and Fission Product Spectroscopy, Caen, EPJ Web of Conferences 62, 01007 (2013).
  3. P. Müller, J. Moazzami-Fallah, J. Szerypo, P.G. Thirolf, C. Weber, Status of the Intrap project at MLLTRAP,
    Verhandl. DPG (VI) 48, HK 69.6 (2013).
  4. L.v.d. Wense, P.G. Thirolf, D. Kalb, M. Laatiaoui, Preparations for an optical access to the lowest excited
    nuclear state in 229Th, Verhandl. DPG (VI) 48, HK 31.6 (2013).
  5. L. Csige, D.M. Filipescu, T. Glodariou, J. Gulyas, M. Guenther, D. Habs, H.J. Karwowski, A. Krasznahorkay, G.C. Rich, L. Stroe, O. Tesileanu, P.G. Thirolf, Photofission of 238U induced by a brilliant, quasi-monochromatic, Compton-backscattered gamma beam, Verhandl. DPG (VI) 48, HK 64.5 (2013).
  6. R. Meissner, P. Thirolf, C. Weber, Fully-automated field mapping of a dipole magnet of a multi-passage spectrometer (MPS), Verhandl. DPG (VI) 48, HK 52.25 (2013).


Books / Book Chapters:

Book Chapter:
K. Parodi, Monte Carlo calculations for PET-based treatment verification of ion beam therapy, in “Monte Carlo Applications in Radiation Therapy” edited by Frank Verhaegen and Joao Seco, CRC Press, 2013

 

Bachelor Thesis intern:

  1. M. März, Experimental Determination of the Proton Induced Excitation Function of 13N
  2. B. Gerling, Monitoring of the beam current in a proton induced activation experiment of a SiO2 target
  3. M. Aumiller, Entwicklung und Charakterisierung eines “Thick-GEM” Gasdetektors zum ortsempfindlichen Nachweis von Spaltfragmenten
  4. A. Augenstein, Development of a thermally stabilized sample holder for Coincidence Doppler Broadening at the NEPOMUC positron source of the FRM-2, Bachelor thesis, LMU, 2013
  5. C. Ammar, Bestimmung der biologischen Abbaukoeffizienten von strahlungsinduzierten ß+ Emittern nach Bestrahlung mit Protonen und 12C Ionen
  6. K. Baumann, Untersuchung der lateralen Abhängigkeit zweier Flachbettscaner bei der Filmdosimetrie mit Gafchromic EBT3 Filmen
  7. R. Berger, Qualitätssicherungsmessungen mit dem RadEye Detektor
  8. B. Gilg, Strahlenschädigungsmessungen mit dem RadEye™ Detektor
  9. A. Kakoschke, Qualitätssicherungsmessungen in der Strahlentherapie mit Gafchromischen Filmen 
  10. P. Leitl, Untersuchung des Nachdunklungs-Effekts von Gafchromic EBT3-Filmen
  11. R. Lange, Fabrication and Characterization of Free-Standing, thin Gold Films
  12. F. Lermer, Untersuchung der Laserintensitätsverteilung in Bezug auf die Raumphasenverformung
  13. T. Rumpf, Charakterisierung der laserinduzierten Zerstörschwellen von Spiegeln und spektrales Verhalten im Femtosekunden-Bereich
  14. S. Seuferling, Fabrication of Shaped-Targets using Parylene
  15. T. Wagner, A high dynamic range camera for pulsed laser applications, Eine Kamera mit einem dynamischen Bereich von 20 bit für gepulste Lasersysteme 

Bachelor Thesis extern:

  1. A. Augenstein, Development of a thermally stabilized sample holder for Coincidence Doppler Broadening at the NEPOMUC positron source of the FRM-2
  2. L. Vomacka, Bestimmung von Nichtlinearitäten im Signalverlauf bei der Quantifizierung der MR-Herzperfusion (LMU Klinikum Großhadern, Radiologie)
  3. E. Weber, Test und Optimierung einer Methode zur Elimination von physiologisch induzierten Bewegungen in der myokardialen Plaque-Bildgebung mittels Positronen-Emissions-Tomographie (LMU Klinikum Großhadern, Nuklearmedizin)
  4. T. Dänzer, Vergleich von berechneter und gemessener Energiedosis in  inhomogenen Phantomen (LMU Klinikum Großhadern, Strahlentherapie)
  5. N. Stocker, Methoden zur Dosisberechnung in der Strahlentherapie bei Durchstrahlung einer Lagerungshilfe unter Verwendung der Algorithmen Pencil Beam und Collapsed Cone(LMU Klinikum Großhadern, Strahlentherapie)
  6. M. Weick-Kleemann, Dosimetrische Charakterisierung der Spotshape für zwei verschiedene Beamlines derselben Protonentherapieanlag (RPTC  München)

 Master Thesis intern:

  1. C. Gäbisch, Experimental studies of the ionoacoustic effect with 20 MeV protons in water (LMU-MP, HZM, HM)

Master Thesis extern:

  1. S. Trinkl, Weiterentwicklung eines elektronischen Photonendosimeters (HZM, Institut für Strahlenschutz)
  2. P. Sterflinger, Laserinduzierte Fluoreszenz-Lebensdauer-Bildgebung Laserforschungslabor, LMU Klinikum Großhadern)
  3. S. Hieber, Untersuchung der Positioniergenauigkeit von Patienten in der Strahlentherapie (LMU Klinikum Großhadern, Strahlentherapie)