Experimental Medical Physics
print


Breadcrumb Navigation


Content

2014

Peer-reviewed journals

Medical Physics

  1. C. Lang, D. Habs, K. Parodi, P.G. Thirolf, Submillimeter nuclear medical imaging with increased sensitivity
    in positron emission tomography using beta-gamma coincidences,
    Jour. of Instrumentation 9 (2014) P01008
  2. K. Frey , J. Bauer, D. Unholtz, C. Kurz, M. Krämer, T. Bortfeld, K. Parodi. TPS(PET)-A TPS-based
    approach for in vivo dose verification with PET in proton therapy
    , Phys. Med. Biol. 2014 Jan 6;59(1):1-21.
  3. P.R. Bolton, M. Borghesi, C. Brenner, D.C. Carroll, C. De Martinis, A. Flacco, V. Floquet, J. Fuchs, P.  Gallegos,  D. Giove, J.S. Green, S. Green, B. Jones, D. Kirby, P. McKenna, D. Neely, F. Nuesslin, R. Prasad, S. Reinhardt, M. Roth, U. Schramm, G.G. Scott, S. Ter-Avetisyan, M. Tolley, G. Turchetti, J.J. Wilkens, Instrumentation for diagnostics and control of laser-accelerated proton (ion) beamsPhysica Medica   (2014) 255-270.
  4. P.G. Thirolf, C. Lang, S. Aldawood, H.G. v.d. Kolff, L. Maier, D.R. Schaart, K. Parodi,
    Development of a Compton Camera for Online Range Monitoring of Laser-Accelerated Proton Beams via Prompt-Gamma Detection, EPJ Web of Conferences 66, 11036 (2014).
  5. O. Zlobinskaya, C. Siebenwirth, C. Greubel, V. Hable, R. Hertenberger, N. Humble, S. Reinhardt, D. Michalski, B. Röper, G. Multhoff, G. Dollinger, J. J. Wilkens, and T. E. Schmid, The effects of ultra-high dose rate proton irradiation on growth delay in the treatment of human tumor xenografts in nude mice, Radiat. Res. 181 (2), 177-83 (2014).
  6. K. Parodi, Heavy Ion radiography and tomography, Phys. Med. 2014: S1120-1797

  7. J. Schwaab, M. Prall, C. Sarti, R. Kaderka, C. Bert, C. Kurz, K. Parodi, M. Günther, J. Jenne, Ultrasound tracking for intra-fractional motion compensation in radiation therapy. Phys Med. 2014  S1120-1797
  8. M. Prall, R. Kaderka, N. Saito, C. Graeff, C. Bert, M. Durante, K.Parodi, J. Schwaab, C. Sarti, J. Jenne, Ion beam tracking using ultrasound motion detection. Med Phys. 2014 041708
  9. G. Dedes, M. Pinto, D. Dauvergne, N. Freud, J. Krimmer, J. M. Létang, C. Ray, E. Testa, Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring, Phys. Med. Biol. 59 1747
  10. F. Roellinghoff, A. Benilov, D. Dauvergne, G. Dedes, N. Freud, G. Janssens, J. Krimmer, J. M. Létang, M. Pinto, D. Prieels, C. Ray, J. Smeets, F. Stichelbaut, E. Testa, Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera, Phys. Med. Biol. 59 1327
  11. I. Rinaldi, S. Brons, O. Jäkel B. Voss, K. Parodi, Experimental investigations on carbon ion scanning radiography using a range telescope, Phys. Med. Biol. 59:3041-3057, 2014.
  12. C. Gianoli, M. Riboldi, C. Kurz, E. De Bernardi, J. Bauer, G. Fontana, M. Ciocca, K. Parodi, G. Baroni, PET-CT scanner characterization for PET raw data use in biomedical research, Comput. Med. Imaging Graph. S0895-6111 (14)00040-8, 2014.
  13. F. Kamp, S. Brüningk, G. Cabal, A. Mairani, K. Parodi, JJ.Wilkens, Variance-based sensitivity analysis of biological uncertainties in carbon ion therapy, Phys Med. 30(5):583-7, 2014.
  14. F. Janssen, G. Landry, P. Cambraia Lopes, G. Dedes, J. Smeets, DR Schaart, K. Parodi, F. Verhaegen, Factors influencing the accuracy of beam range estimation in proton therapy using prompt gamma emission, Phys Med Biol. 59(15) 4427-4441, 2014.
  15. J. Bauer, F. Sommerer, A. Mairani, D. Unholtz, R. Farook, J. Handrack, K. Frey, T. Marcelos, T. Tessonnier, S. Ecker, B. Ackermann, M. Ellerbrock, J. Debus, K. Parodi, Integration and evaluation of automated Monte Carlo simulations in the clinical practice of scanned proton and carbon ion beam therapy, Phys Med Biol. 2014 Aug 21;59(16):4635-59. doi: 10.1088/0031-9155/59/16/4635.
  16. I. Rinaldi, S. Brons, O. Jäkel, B. Voss, K. Parodi, A method to increase the nominal range resolution of a stack of parallel-plate ionization chambers, Phys Med Biol. 2014 Sep 21;59(18):5501-15 doi: 10.1088/0031-9155/59/18/5501.
  17. K. Frey, D. Unholtz, J. Bauer, J. Debus, CH Min, T. Bortfeld, H. Paganetti, K. Parodi,  Automation and uncertainty analysis of a method for in-vivo range verification in particle therapy, Phys Med Biol. 2014 Sep 11;59(19):5903-5919.
  18. G. Fonseca, G.Landry, S. White, M. D’Amours, H. Yoriyaz, L. Beaulieu, B. Reniers, F. Verhaegen, The use of tetrahedral mesh geometries in Monte Carlo simulation of applicator based brachytherapy dose distributions, Physics in medicine and biology (2014) vol. 59 (19) pp. 5921-5935.
  19. C. Ammar, K. Frey, J. Bauer, C. Melzig, S. Chiblak, M. Hildebrandt, D. Unholtz, C. Kurz, S. Brons, J. Debus, A. Abdollahi, K. Parodi, Comparing the biological washout of β+-activity induced in mice brain after 12C-ion and proton irradiation, Phys Med Biol. 2014 Dec 7;59(23):7229-44.
  20. C. Gianoli, J. Bauer, M. Riboldi, E. De Bernardi, G. Fattori, G. Baselli, J. Debus, K. Parodi, G. Baroni,
    Regional MLEM reconstruction strategy for PET-based treatment verification in ion beam radiotherapyPhys Med Biol. 2014 Nov 21;59(22):6979-95.

 

 Nuclear Physics

  1. S. Ilieva, M. Thürauf, Th. Kröll, R. Krücken, T. Behrens, V. Bildstein, S. Bönig, P. Butler, J. Cederkäll, T. Davinson, P. Delahaye, J. Diriken, A. Ekström, F. Finke, L. Fraile, S. Franchoo, G. Georgiev, R. Gernhäuser, D. Habs, A. Hurst, M. Huyse, O. Ivanov, J. Iwanicki, P. Kent, O. Kester, U. Köster, R. Lutter, M. Mahgoub, D. Martin, P. Mayet, P. Maierbeck, T. Morgan, O. Niedermeier, M. Pantea, T. R. Rodriguez, H. Scheit, A. Scherillo, D. Schwalm, M. Seidlitz, T. Sieber, G. Simpson, I. Stefanescu, P. Thirolf, J. Van de Walle, P. Van Duppen, D. Voulot, N. Warr, W. Weinzierl, D. Weisshaar, and F. Wenander,  Coulomb excitation of neutron-rich Cd isotopes, Phys. Rev. C 89, 014313 (2014).
  2. C. Weber, R. Meissner, P. Müller, P.G. Thirolf, Status of the MLLTRAP setup and future plans, Hyperfine Interactions 227, 247 (2014).
  3. P.G. Thirolf and D. Habs, Bright Perspectives for Nuclear Photonics, Eur. Phys. Jour. Special Topics 223, 1213 (2014).
  4. S. Bönig, S. Ilieva, T. Kröll, M. Scheck, D. Balabanski, C. Bauer, A. Blazhev, T. Bloch, D. Deleanu, J. Diriken, P. Fernier, R. Gernhäuser, K. Hadýnska-Kl ̨ek, A. Jungclaus, R. Lutter, A. Negret, K. Nowak, R. Orlandi, J. Pakarinen, G. Rainovski, T.R. Rodríguez, M. von Schmid, M. Seidlitz, B. Siebeck, G.S. Simpson, A. Illana Sisón, R. Stegmann, T. Stora, P.G. Thirolf, M. Thürauf, M.J. Vermeulen, D. Voulot, N. Warr, F. Wenander, H. De Witte, and MINIBALL Collaboration, Quadrupole collectivity in neutron-rich Cd isotopes, Eur.Phys. Jour. Web of Conf. 66, 02012 (2014).
  5. C. Droese, S. Eliseev, K. Blaum, M. Block, F. Herfurth, M. Laatiaoui, F. Lautenschlaeger, E. Minaya Ramirez, L. Schweikhard, V.V. Simon, P.G. Thirolf, The cryogenic gas stopping cell of SHIPTRAP,
    Nucl. Instr. Meth. B 338, 126-138 (2014).
  6. J. Jolie, J.-M. Regis, D. Wilmsen, S. Ahmed, M. Pfeiffer, N. Saed-Samii, N. Warr, A. Blanc, M. Jentschel, U. Köster, P. Mutti, T. Soldner, G. Simpson, G. De France, W. Urban, A.M. Bruce, O.J. Roberts, L.M. Fraile, V. Paziy, A. Ignatov, S. Ilieva, Th. Kröll, M. Scheck, M. Thürauf, D. Ivanova, S. Kisyov, S. Lalkovski, Zs. Podolyak, P.H. Regan, W. Korten, D. Habs, P.G. Thirolf, C.A. Ur,
    First results of the (n,gamma) EXILL campaigns at the Institut Laue Langevin using EXOGAM and FATIMA, Jour. Phys. Conf. Ser. 533, 012026 (2014)

 

 Laser-Ion-Acceleration

Dependence of laser-driven coherent synchrotron emission efficiency on pulse ellipticity and implications for polarization gating

M. Yeung, B. Dromey, S. Cousens, T. Dzelzainis, D. Kiefer, J. Schreiber, J. H. Bin, W. Ma, C. Kreuzer, J. Meyer-ter-Vehn, M. J. V. Streeter, P. S. Foster, S. Rykovanov, and M. Zepf
Physical Review Letters 112, 123902 (2014)

Bright subcycle XUV pulse from a single dense relativistic electron sheet

W.J. Ma, J.H. Bin, H.Y. Wang, M. Yeung, C. Kreuzer, M. Streeter, P.S. Foster, S. Cousens, D. Kiefer, B. Dromey, X.Q. Yan, M. Zepf, J. Meyer-ter-Vehn, and J. Schreiber
arXiv:1402.4369 (2014)

Relativistic plasma optics enabled by near-critical density nanostructured material

J.H. Bin, W.J. Ma, H.Y. Wang, M.J.V. Streeter, C. Kreuzer, D. Kiefer, M. Yeung, S. Cousens, P.S. Foster, B. Dromey, X.Q. Yan, J. Meyer-ter-Vehn, M. Zepf, and J. Schreiber
arXiv:1402.4301 (2014)

Laser-driven three-stage heavy-ion acceleration from relativistic laser-plasma interaction

H. Y. Wang, C. Lin, B. Liu, Z. M. Sheng, H. Y. Lu, W. J. Ma, J. H. Bin, J. Schreiber, X. T. He, J. E. Chen, M. Zepf, and X. Q. Yan
Physical Review E 89, 013107 (2014)

Abstracts and conference proceedings

Medical Physics

  1. Gianoli C, Fattori G, Riboldi M, Rinaldi I, Dedes G, Parodi K, Baroni G. Projection-based deformable registration for tomographic imaging in ion beam therapy. InNuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2014 IEEE 2014 Nov 8 (pp. 1-4). IEEE.
  2. Gianoli C, Ricotti R, De Bernardi E, Riboldi M, Bauer J, Debus J, Baroni G, Parodi K. Clinical investigations of a 4D ML reconstruction strategy for PET-based treatment verification in ion beam therapy. InNuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2014 IEEE 2014 Nov 8 (pp. 1-4). IEEE.
  3. G. Dedes, G. Landry, J. Handrack, G. Cabal, R. Nijhuis, M. Soehn, M. Reiner, U. Ganswindt, C. Thieke, F. Kamp, J.J. Wilkens, C. Belka, K. Parodi, Monte Carlo study on the sensitivity of positron and prompt-gamma imaging to proton range variations due to inter-fractional anatomical changes in head an neck and prostate cancer patients, Joint Conference of the SSRMP, DGMP, OGMP, Zurich, Abstractband ISBN: 987-3-9816508-5-3, p. 146-7, 2014.
  4. G. Landry, G. Dedes, J. Handrack, G. Cabal, R. Nijhuis, M. Soehn, M. Reiner, U. Ganswindt, C. Thieke, G. Janssens, J. Orban de Xivry, C. Paganelli, F. Kamp, M. Riboldi, J.J. Wilkens, G. Baroni, C. Belka, K. Parodi, A novel approach to estimate the dosimetric influence of anatomical changes in head and neck cancer patients undergoing proton therapy using daily CBCT imaging, Joint Conference of the SSRMP, DGMP, OGMP, Zurich,  Abstractband ISBN 987-3-9816508-5-3, p. 144-5, 2014.

  5. G. Dedes, N. Arbor, D. Dauvergne, J.-M. Letang, K. Parodi, C. T. Quinones, E. Testa, S. Rit, Assessment of the performance of proton computed tomography for use in proton therapy treatment planning - Monte
    Carlo study, Joint Conference of the SSRMP, DGMP, OGMP, Zurich, Abstractband ISBN 987-3-9816508-5-3, p. 33-4 2014.

  6. P.G. Thirolf, S. Aldawood, M. Böhmer, J. Bortfeldt, I. Castelhano, R. Gernhöuser, H. v.d. Kolff, C. Lang, L. Maier, D.R. Schaart, K. Parodi, Status of the Compton Camera prototype for online range verification of
    proton beam
    s, Joint Conference of the SSRMP, DGMP, OGMP, Zurich, Abstractband ISBN 987-3-9816508-5-3, p. 130-3, 2014.

  7. I. Rinaldi, T. Marcelos, L. Magallanes, S. Brons, O. Jäkel, M. Takechi, B. Voss, K. Parodi, Carbon ion radiography and tomography using beam scanning and a range telescope, Joint Conference of the SSRMP, DGMP, OGMP, Zurich, Abstractband ISBN 987-3-9816508-5-3, p. 76, 2014.

  8. K. Parodi, Introductory lecture: Motion management, Joint Conference of the SSRMP, DGMP, OGMP, Zurich, Abstractband ISBN 987-3-9816508-5-3, p. 97, 2014.

  9. S. Reinhardt, W. Assmann, S. Kellnberger, M. Omar, A. Fink, C. Gäbisch, P. Thirolf, M. Moser, G. Dollinger, V. Ntziachristos, K.Parodi, Range verification by measurement of the acoustic signal from the Bragg Paek,
    Joint Conference of the SSRMP, DGMP, OGMP, Zurich, Abstractband ISBN 987-3-9816508-5-3, p. 133, 2014.

  10. K Parodi, D Dauvergne and J Kruse, The ESTRO-AAPM Joint Symposium On Imaging for Proton Treatment Planning and Guidance 56th Annual Meeting of AAPM, July 20-24, 2014, Austin (USA) Med. Phys. 41 , 506 (2014).
  11. L. Magallanes, S. Brons, T. Marcelos, M. Takechi, B. Voss, O. Jäkel, I. Rinaldi and K. Parodi, On the role of ion-based imaging methods in modern ion beam therapy, AIP Conf. Proc. 1626 , 142 (2014).
  12. I Rinaldi, T Marcelos, L Magallanes, M Takechi, S Brons, O Jaekel, B Voss and K Parodi Experimental Investigations On Ion Radiography with Beam Scanning Using a Range Telescope 56th Annual Meeting of AAPM, July 20-24, 2014, Austin (USA) Med. Phys. 41 , 496 (2014).
  13. P.G. Thirolf, S. Aldawood, M. Boehmer, J. Bortfeldt, I. Castelhano, R. Gernhaeuser, H. v.d. Kolff, C. Lang, L. Maier, D.R. Schaart and K. Parodi, Development of a Compton Camera Prototype for Online Range Verification of Laser-Accelerated Proton Beams, 56th Annual Meeting of AAPM, July 20-24, 2014, Austin (USA), Med. Phys. 41 , 165 (2014).
  14. S. Reinhardt, W. Assmann, S. Kellnberger, M. Omar, A. Fink, C. Gaebisch, P. Thirolf, M. Moser, G. Dollinger, G. Sergiadis, V. Ntziachristos and K. Parodi, Acoustic Signal From the Bragg Peak for Range Verification in Proton Therapy, 56th Annual Meeting of AAPM, July 20-24, 2014, Austin (USA) Med. Phys. 41 , 495 (2014).
  15. S. Aldawood, C. Lang, H. v.d. Kolff, L. Maier, R. Lutter, J. Bortfeldt, K. Parodi, P.G. Thirolf, Development of a Compton camera for online ion beam range verification via prompt $\gamma$ detection,
    Verhandl. DPG (VI) 49, HK 64.7 (2014).
  16. B. Tegetmeyer, S. Aldawood, H. v.d. Kolff, C. Lang, K. Parodi, P. Thirolf, Towards reaction cross section measurements of beta+ emitters produced in hadron therapy,
    Verhandl. DPG (VI) 49, HK 46.38 (2014).
  17. F. Kamp, G. Cabal, A. Mairani, K. Parodi, J.J. Wilkens, D.J. Carlson, Predicting the Relative Biological Effectiveness of Carbon Ion Radiotherapy Beams using the Mechanistic Repair-Misrepair-Fixation (RMF) Model and Nuclear Fragment Spectra, Int J Rad Oncol Biol Phys Issue 1, Supplement, Page S849, 2014.
  18. S. Kantz, K. Huber, H. Weingandt, M. Reiner, C. Belka, K. Parodi, M. Söhn, Nachweisbarkeit patientenrelevanter Fehler in der Gamma-Analyse plan-individueller 2D IMRT-QA, Strahlentherapie und Onkologie · Suppl 1, p.40, 2014.

  19. G. Dedes, K. Parodi, Monte Carlo modeling and image-guidance in particle therapy, Phys. Med. Volume 30, Supplement 1, p. e4, 2014.

  20. J. Bauer, C. Kurz, D. Unholtz, K. Frey, S.E. Combs, J. Debus, K. Parodi, PET/CT-based verification of scanned proton and carbon ion treatment at HIT – an overview, Radiother. Oncol. Vol. 110, Suppl. 1, pS9, 2014.

  21. C. Gianoli, G. Baroni, J. Bauer, C. Kurz, K. Parodi, M. Riboldi, Motion compensated reconstructions in PET-based ion beam treatment verification for moving target, Radiother. Oncol. Vol. 110, Suppl. 1, pS38, 2014.

  22. F. Janssen, G. Landry, K. Parodi, D.R. Schaart, P. Cambraia Lopes, F. Verhaegen, Robustness of range prediction in proton therapy using prompt gamma emission, Radiother. Oncol. Vol. 110, Suppl. 1, pS45, 2014.

  23. G. Landry, J. Seco, K. Parodi, F. Verhaegen, Dual energy CT to reduce range uncertainties in
    hadrontherapy, Radiother. Oncol. Vol. 110, Suppl. 1, pS57, 2014.

  24. L. Magallanes, V. Bernd, S. Brons, O. Jäkel, K. Parodi, I. Rinaldi, M. Takechi, Ongoing investigations on ion-based radiography and tomography, Radiother. Oncol. Vol. 110, Suppl. 1, pS61, 2014.

  25. M. Mori, M. Ciocca, A. Fontana, A. Mairani, K. Parodi, A. Rotondi, Parameterization of lateral dose profiles for proton therapy application at CNAO, Radiother. Oncol. Vol. 110, Suppl. 1, pS69, 2014.

  26. K. Parodi, W. Assmann, S. Kellnberger, M. Omar, C. Gäbisch, S. Reinhardt, P.G. Thirolf, M. Moser, G. Dollinger, T. Hellerer, G. Sergiadis, V. Ntziachristos, Experimental characterization of acoustic detection and imaging for Bragg peak localization in proton therapy, Radiother. Oncol. Vol. 110, Suppl. 1, pS73, 2014.

  27. R. Rescigno, J. Baudot, S. Brons, D. Dauvergne, C. Finck, D. Juliani, J. Krimmer, K. Parodi, C. Ray, V. Reithinger, I. Rinaldi, M. Rousseau, E. Testa, M. Winter, Proton Interaction Vertex Imaging for carbon therapy quality control, Radiother. Oncol. Vol. 110, Suppl. 1, pS81, 2014.

  28. K. Stützer, W. Enghardt, M. Priegnitz, C. Bert, N. Saito, K. Parodi, F. Fiedler, The (non-) detectability of failures in motion mitigated ion beam delivery by means of in-beam PET, Radiother. Oncol. Vol. 110, Suppl. 1, pS93, 2014.

  29. P.G. Thirolf, Novel detectors for range assessment in particle therapy, Radiother. Oncol. Vol. 110, Suppl. 1, pS94, 2014.

  30. M. Riboldi, C. Bert, K. Parodi, D. Sarrut, G. Baroni, "4D" imaging for motion, Radiother. Oncol. Vol. 111, Suppl. 1, p97, 2014.

  31. T. Bortfeld, G. El Fakhri, K. Grogg, H. Paganetti, K. Parodi, C. Richter, J. Seco, J. Verburg, B. Winey, X. Zhu, Latest developments in in-vivo dose and range imaging, Radiother. Oncol. Vol. 111, Suppl. 1, p98, 2014.

  32. S. Reinhardt, S. Kantz, R. Berger, M. Reiner, W. Assmann, K. Parodi, A pixel detector system for QA measurements, Radiother. Oncol. Vol. 111, Suppl. 1, p241, 2014.

Nuclear Physics:

  1.  J. Jolie, J.-M. Regis, D. Wilmsen, S. Ahmed, M. Pfeiffer, N.S. Samii, N. Warr, P. Thirolf, D. Habs, EXILL Collaboration, FATIMA collaboration, First results of the (n,gamma) EXILL campaigns at the Institut Laue Langevin, Verhandl. DPG (VI) 49, HK 11.1 (2014).
  2.  L. v.d. Wense, B. Seiferle, P. Thirolf, M. Laatiaoui, Preparations for an optical access to the lowest nuclear excitation in 229Th, Verhandl. DPG (VI) 49, HK 32.6 (2014).
  3. B. Seiferle, L. v.d. Wense, P. Thirolf, M. Laatiaoui, Preparation of an experiment to directly detect the deexcitation of the 229mTh nuclear isomer, Verhandl. DPG (VI) 49, HK 46.19 (2014).
  4. C. Weber, R. Meissner, P. Müller, P. Thirolf, Status of the MLLTRAP system, Verhandl. DPG (VI) 49, HK 48.4 (2014).


Thesis:

PhD:

  1. Ch. Kurz, 4D offline PET-based treatment verification in ion beam therapy: experimental and clinical evaluation

Master Thesis (internal):

  1. H. v.d. Kolff, Characterization of the absorbing detector component of a Compton camera designed for beam range verification in hadron therapy, Master thesis, TU Delft/LMU Munich
  2. M. Baumgartl, PET-based Hadrontherapy Monitoring: Monte Carlo Simulations for Nuclear Interaction studies in Phantoms (LMU / CNRS Orsay)
  3. S. Lehrack, An automatic laser beam delivery alignment for LEX and CALA / Eine automatische Ausrichtung der Laser-Beam-Delivery für LEX und CALA
  4. I. Castelhano, Development of a Compton Camera for Prompt-Gamma Detection in Hadron therapy, Univ. Lisbon/LMU Munich
  5. B. Tegetmeyer, Measurement of the production cross section of the medically relevant β+ emitter 13N
  6. F. Englbrecht, Experimental based Monte Carlo modeling of a clinical proton beam
  7. M. Würl, PET activation studies at a cyclotron-based proton therapy facility, Experiments and Monte Carlo simulations
  8. E. Seifert, Entwicklung einer Routine zur Verifizierung von Protonenbestrahlungsplänen
    Friedrich-Alexander-Universität Erlangen-Nürnberg / LMU
  9. G. Giovannini, Variability of the Relative Biological Effectiveness and range predictions for Proton Therapy patienst cases
    University of Pavia / LMU
  10. T. dos Santos Marcelos, Carbon ion radiography and tomography: a Monte Carlo study
    University of Lisbon / LMU
  11. C. Marcon, Towards a fast proton dose calculation: evaluating the accuracy and time performance of different pencil beam algorithms in proton therapy (Universita degli studi dell Insubria, LMU Munich)
  12. T. Vannieuwenhuyse: Optimierung eines Doppelkristallmonochromators für das Neutronen-Tomographie-Instrument ANTARES am FRM II

 Master Thesis (external):

  1. M. Großmann, Entwicklung und Evalution von Auswertungsalgorithmen bei fluoreszenzspektroskopischen Messungen von Zink-Protporphyrin im Gewebe (Diplomarbeit) (Laserforschungslabor, LMU Klinikum Großhadern)
  2. K. Huber, Relevanz der Maschinentoleranz für klinische IMRT-Anwendung
    (Strahlentherapie, LMU Klinikum Großhadern)
  3. F. Bergmeier, Verbesserung der Neutronendosimetrie von meV bis GeV (HGMU)
  4. S. Neppl, Picket fence and beyond - what cna 2D array measurments and the gamma index method tell about leaf misalignment ? (Klinik und Poliklinik für Strahlentherapie und Radioonkologie, Klinikum Großhandern) 

 Bachelor Thesis (internal):

  1. B. Kopp, Implementation of a Spot Scanning coordinate system in a Monte Carlo Simulation for quality assurance of a proton treatment facility (mit RPTC)
  2. P. Freiwang, Messung der Zeitstruktur eines gepulsten 20MeV-Protonenstrahls
  3. A. Edlich, k-Wave-Simulationen zur Ionoakustik
  4. A. Mayr, QA mit RadEye
  5. D. Hahner, Entwicklung eines automatischen Positionierungs-und Ausrichtungssysems
  6. C. Zoellner, Phantom study on cone beam computed tomography based proton stopping power estimation using deformable image registration
  7. Y. Assano, Monte-Carlo Studie zur Analyse von Protonen Computertomographien und den Auswirkungen auf die Bestrahlungsplanung
  8. J. Handrack, On the deformation of computed tomography images for new adaptive strategies in proton radio therapy, Heidelberg University / LMU

Bachelor Thesis (external):

  1. L. Hassan, Aufbau und Inbetriebnahme eines Domonstrationsaufbaus zu optischen Kohärenztomographie (HM, Mechatronik)
  2. J. Riegger, Vergleich der Genauigkeit der Algorithmen Pencil Beamund Callapsed Cone an Phantomen verschiedener Dichtezusammensetzung und Geometrie (LMU Klinikum Großhadern, Strahlentherapie)
  3. F. Dauenhauer, Optimierung und Charakterisierung eines Ulbricht-Kugel-Messplatzes zur Bestimmung optischer Gewebeparameter (Laserforschungslabor, LMU Klinikum Großhadern)