Experimental Medical Physics
print


Breadcrumb Navigation


Content

2019

 2018 2017  2016  2015  2014  2013  2012  2011  2010

Medical Physics

Peer-reviewed journals:

  1. Meyer S, Kamp F, Tessonnier T, Mairani A, Belka C, Carlson DJ, Gianoli C, Parodi K.: Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning. Phys Med Biol. 2019 doi: 10.1088/1361-6560/ab0fdf. [Epub ahead of print]
  2. Landry G, Dörringer F, Si-Mohamed S, Douek P, Abascal JFPJ, Peyrin F, Almeida IP, Verhaegen F, Rinaldi I, Parodi K, Rit S: Technical Note: Relative proton stopping power estimation from virtual monoenergetic images reconstructed from dual-layer computed tomography. Med Phys. 2019 doi: 10.1002/mp.13404. [Epub ahead of print] Select item 30599609
  3. Würl M, Englbrecht FS, Lehrack S, Gianoli C, Lindner FH, Rösch TF, Haffa D, Olivari F, Petasecca M, Lerch MLF, Pogossov A, Tran LT, Assmann W, Schreiber J, Rosenfeld AB, Parodi K.: Time-of-flight spectrometry of ultra-short, polyenergetic proton bunches. Rev Sci Instrum. 2018;89:123302. doi: 10.1063/1.5052059.
    Select item 305240
  4. Hofmann T, Pinto M, Mohammadi A, Nitta M, Nishikido F, Iwao Y, Tashima H, Yoshida E, Chacon A, Safavi-Naeini M, Rosenfeld A, Yamaya T, Parodi K.: Dose reconstruction from PET images in carbon ion therapy: a deconvolution approach. Phys Med Biol. 2019;64: 025011. doi: 10.1088/1361-6560/aaf676. Select item 30523998
  5. Landry G, Hansen D, Kamp F, Li M, Hoyle B, Weller J, Parodi K, Belka C, Kurz C.: Comparing Unet training with three different datasets to correct CBCT images for prostate radiotherapy dose calculations. Phys Med Biol. 2019;64: 035011. doi: 10.1088/1361-6560/aaf496.
  6. Lehrack S, Assmann W and Parodi K: Ionoacoustics for range monitoring of proton therapy, IOP Conf. Series: Journal of Physics: Conf. Series 2019; 1154: 012015 doi:10.1088/1742-6596/1154/1/012015
  7. Hansen DC, Landry G, Kamp F, Li M, Belka C, Parodi K, Kurz C: Erratum: "ScatterNet: A convolutional neural network for cone-beam CT intensity correction" Med Phys. 2019 2538. doi: 10.1002/mp.13469
  8. Hofmann T, Fochi A, Parodi K, Pinto M: Prediction of positron emitter distributions for range monitoring in carbon ion therapy: an analytical approach, Phys Med Biol. 2019 Apr 10. doi: 10.1088/1361-6560/ab17f9. [Epub ahead of print]
  9. Gianoli C, Meyer S, Magallanes L, Paganelli C, Baroni G, Parodi K: Analytical simulator of proton radiography and tomography for different detector configurations, Phys Med. 2019; 59:92-99. doi: 10.1016/j.ejmp.2019.03.002
  10. Freislederer P, von Münchow A, Kamp F, Heinz C, Gerum S, Corradini S, SÖhn M, Reiner M, Roeder F, Floca R, Alber M, Belka C, Parodi K: Comparison of Planned Dose on Different CT Image Sets to Four-dimensional Monte Carlo Dose Recalculation Using the Patients Actual Breathing Trace for Lung Stereotactic Body Radiation Therapy. Med Phys. 2019 May 10. doi: 10.1002/mp.13579. [Epub ahead of print]
  11. Mohammadi A, Tashima H, Iwao Y, Takyu S, Akamatsu G, Nishikido F, Yoshida E, Kitagawa A, Parodi K, Yamaya T.: Range verification of radioactive ion beams of 11C and 15O using in-beam PET imaging, Phys Med Biol. 2019 Jul 16;64(14):145014. doi: 10.1088/1361-6560/ab25ce. PMID:31146265

  12. Dickmann J, Wesp P, Rädler M, Rit S, Pankuch M, Johnson RP, Bashkirov V, Schulte RW, Parodi K, Landry G, Dedes G.: Prediction of image noise contributions in proton computed tomography and comparison to measurements, Phys Med Biol. 2019 Jul 16;64(14):145016. doi: 10.1088/1361-6560/ab2474. PMID:
    31125986

  13. Chacon A, Guatelli S, Rutherford H, Bolst D, Mohammadi A, Ahmed A, Nitta M, Nishikido F, Iwao Y, Tashima H, Yoshida E, Akamatsu G, Takyu S, Kitagawa A, Hofmann T, Pinto M, Franklin DR, Parodi K, Yamaya T, Rosenfeld A, Safavi-Naeini M.: Comparative study of alternative Geant4 hadronic ion inelastic physics models for prediction of positron-emitting radionuclide production in carbon and oxygen ion therapy, Phys Med Biol. 2019 Aug 7;64(15):155014. doi: 10.1088/1361-6560/ab2752. PMID: 31167173

  14. Hofmaier J, Bodensohn R, Garny S, Hadi I, Fleischmann DF, Eder M, Dinc Y, Reiner M, Corradini S, Parodi K, Belka C, Niyazi M.: Single isocenter stereotactic radiosurgery for patients with multiple brain metastases: dosimetric comparison of VMAT and a dedicated DCAT planning tool, Radiat Oncol. 2019 Jun 11;14(1):103. doi: 10.1186/s13014-019-1315-z. PMID: 31186023

  15. Dedes G, Dickmann J, Niepel KB, Wesp P, Johnson RP, Pankuch M, Bashkirov VA, Rit S, Volz L, Schulte RW, Landry G, Parodi K.: Experimental comparison of proton CT and dual energy X-ray CT for relative stopping power estimation in proton therapy, Phys Med Biol. 2019 Jun 20. doi: 10.1088/1361-6560/ab2b72. [Epub ahead of print] PMID: 31220814

  16. Parodi K, Assmann W, Belka C, Bortfeldt J, Clevert DA, Dedes G, Kalunga R, Kundel S, Kurichiyanil N, Lämmer P, Lascaud J, Lauber K, Lovatti G, Meyer S, Nitta M, Pinto M, Safari MJ, Schnürle K, Schreiber J, Thirolf PG, Wieser HP, Würl M.: Towards a novel small animal proton irradiation platform: the SIRMIO project, Acta Oncol. 2019 Jul 4:1-6. doi: 10.1080/0284186X.2019.1630752. [Epub ahead of print] PMID: 31271091

  17. Neppl S, Landry G, Kurz C, Hansen DC, Hoyle B, Stöcklein S, Seidensticker M, Weller J, Belka C, Parodi K, Kamp F.: Evaluation of proton and photon dose distributions recalculated on 2D and 3D Unet-generated pseudoCTs from T1-weighted MR head scans, Acta Oncol. 2019 Jul 4:1-6. doi: 10.1080/0284186X.2019.1630754. [Epub ahead of print] PMID: 31271093

  18. Huck SM, Fung GSK, Parodi K, Stierstorfer K.: Technical Note: Sheet-based dynamic beam attenuator - A novel concept for dynamic fluence field modulation in x-ray CT, Med Phys. 2019 Jul 26. doi: 10.1002/mp.13690. [Epub ahead of print] PMID: 31348527

  19. Mein S, Dokic I, Klein C, Tessonnier T, Böhlen TT, Magro G, Bauer J, Ferrari A, Parodi K, Haberer T, Debus J, Abdollahi A, Mairani A.: Biophysical modeling and experimental validation of relative biological effectiveness (RBE) for 4He ion beam therapy, Radiat Oncol. 2019 Jul 11;14(1):123. doi: 10.1186/s13014-019-1295-z. PMID: 31296232

  20. Garau N, Via R, Meschini G, Lee D, Keall P, Riboldi M, Baroni G, Paganelli C. A ROI-based global motion model established on 4DCT and 2D cine-MRI data for MRI-guidance in radiation therapy. Phys Med Biol. 2019 Feb 5;64(4):045002. doi: 10.1088/1361-6560/aafcec.

  21. Meschini G, Paganelli C, Gianoli C, Summers P, Bellomi M, Baroni G, Riboldi M.A clustering approach to 4D MRI retrospective sorting for the investigation of different surrogates. Phys Med. 2019 Feb;58:107-113. doi: 10.1016/j.ejmp.2019.02.003.

  22. Cassetta R, Piersimoni P, Riboldi M, Giacometti V, Bashkirov V, Baroni G, Ordonez C, Coutrakon G, Schulte R. Accuracy of low-dose proton CT image registration for pretreatment alignment verification in reference to planning proton CT. J Appl Clin Med Phys. 2019 Apr;20(4):83-90. doi: 10.1002/acm2.12565.

  23. Dias MFF, Collins-Fekete CA, Baroni G, Riboldi M, Seco J. Theoretical tumor edge detection technique using multiple Bragg peak decomposition in carbon ion therapy. Biomedical Physics & Engineering Express 2019, in press.

  24. Meschini G, Seregni M, Molinelli S, Vai A, Phillips J, Sharp GC, Pella A, Valvo F, Ciocca M, Riboldi M, Paganetti H, Baroni G. Validation of a model for physical dose variations in irregularly moving targets treated with carbon ion beams. Med Phys. 2019 Aug;46(8):3663-3673. doi: 10.1002/mp.13662

  25. Paganelli C, Portoso S, Garau N, Meschini G, Via R, Buizza G, Keall PJ, Riboldi M, Baroni G. Time-resolved volumetric MRI in MRI-guided radiotherapy: an in-silico comparative analysis. Phys Med Biol. 2019 Jul 19. doi: 10.1088/1361-6560/ab33e5. [Epub ahead of print]

  26. Kroll C, Dietrich O, Bortfeldt J, Paganelli C, Baroni G, Kamp F, Neppl S, Belka C, Parodi K, Opel M, Riboldi M. Improving the modelling of susceptibility-induced spatial distortions in MRI-guided extra-cranial radiotherapy. Phys Med Biol. 2019 Sep 13. doi: 10.1088/1361-6560/ab447c. [Epub ahead of print]

     

     

     

     

     

     

     

     



Abstracts and conference proceedings:

  1. T. Binder, M. Kawula, S. Liprandi, G.P. Vinci, F. Schneider, K. Parodi, P.G. Thirolf, Advances in a Silicon Photomultiplier Readout of a Compton Camera, Verhandl. DPG (VI), 54, HK 31.6 (2019).
  2. G.P. Vinci, T. Binder, S. Liprandi, M. Kawula, K. Parodi, and P.G. Thirolf, Performance of a monolithic scintillator studied under realistic conditions in a Compton Camera system, Verhandl. DPG (VI), 54, HK 54.63 (2019).
  3. M. Kawula, S. Liprandi, T. Binder, R. Viegas Rego, B. Hoyle, K. Parodi, P.G. Thirolf, Determination of the photon interaction position in a monolithic scintillator applied in a Compton Camera, Verhandl. DPG (VI), 54, HK 54.75 (2019).
  4. T. Binder, M. Kawula, S. Liprandi, G.P. Vinci, F. Schneider, K. Parodi, P.G. Thirolf,\\
    Advances in a Silicon Photomultiplier Readout of a Compton Camera, \\
    Verhandl. DPG (VI), 54, ST 3.2 (2019)
  5. G.P. Vinci, T. Binder, S. Liprandi, M. Kawula, K. Parodi, P.G. Thirolf, Performance of a monolithic scintillator studied under realistic conditions in a Compton Camera system, Verhandl. DPG (VI), 54, ST 4.5 (2019).
  6. M. Nitta, G. Lovatti, G. Dedes, S. Takyu, M. Safari, T. Binder, G. Vinci, T. Yamaya, K. Parodi, P.G. Thirolf, Investigation of the dependency of properties of a 4-layer DOI PET detector on the scintillator material, Verhandl. DPG (VI), 54, ST 4.6 (2019).
  7. M. Kawula, S. Liprandi, T. Binder, R. Viegas Rego, B. Hoyle, K. Parodi, P.G. Thirolf, Determination of the photon interaction position in a monolithic scintillator applied in a Compton Camera system, Verhandl. DPG (VI), 54, ST 4.8 (2019).
  8. C Paganelli, S Portoso, N Garau, G Meschini, R Via, P Keall, M Riboldi, G Baroni. Comparison of different strategies to derive time-resolved volumetric MRI in MRI-guided radiotherapy. Radiotherapy and Oncology 133, S210-S211
  9. C Kroll, M Opel, C Paganelli, F Kamp, S Neppl, G Baroni, O Dietrich, C Belka, K Parodi, M Riboldi. Simulation of tissue dependent magnetic field susceptibility effects in MRI guided radiotherapy. Radiotherapy and Oncology 133, S554-S555
  10. G Meschini, C Paganelli, G Fontana, A Pella, A Mancin, A Vai, M Riboldi, F Valvo, G Baroni. Validation of respiratory motion modeling through repeated 4DMRI in the abdomen: preliminary results. Radiotherapy and Oncology 133, S533
  11. M Raedler, G Dedes, K Parodi, M Riboldi. Exploring a Novel Concept for Direct Proton Beam Measurement Via Its Magnetic Field: A Simulation Study. MEDICAL PHYSICS 46 (6), E475-E475

Detector Development and High Energy Physics

Laser-Ion-Acceleration

Peer-reviewed journals:

  1. Lindner F. H., McCary E., Jiao X., Ostermayr T. M., Roycroft, R.,Tiwari G., Hegelich B. M., Schreiber J., Thirolf P. G.: En-route to the fission-fusion reaction mechanism: a status update on laser-driven heavy ion acceleration. Plasma Physics and Controlled Fusion 61 (2019) 055002.
  2. Haffa D, Yang R, Bin J, Lehrack S, Brack FE, Ding H, Englbrecht FS, Gao Y, Gebhard J, Gilljohann M, Götzfried J, Hartmann J, Herr S, Hilz P, Kraft SD, Kreuzer C, Kroll F, Lindner FH, Metzkes-Ng J, Ostermayr TM, Ridente E, Rösch TF, Schilling G, Schlenvoigt HP, Speicher M, Taray D, Würl M, Zeil K, Schramm U, Karsch S, Parodi K, Bolton PR, Assmann W, Schreiber J.: I-BEAT: Ultrasonic method for online measurement of the energy distribution of a single ion bunch, Sci Rep. 2019 Apr 30;9(1):6714. doi: 10.1038/s41598-019-42920-5.


Abstracts and conference proceedings:

Nuclear Physics

Peer-reviewed journals:

  1. P.G. Thirolf, B. Seiferle, L. v.d. Wense, Improving our knowledge on the 229mTh isomer: towards a test bench for time variations of fundamental constants, Annalen der Physik 531, 1800391 (2019).
  2. L. v.d. Wense, B. Seiferle, I. Amersdorffer, P.G. Thirolf, Generation of high-quality beams of the thorium isomer 229mTh, Journal of Visualized Experiments 147, e58516 (2019).
  3. L. v.d. Wense, B. Seiferle, C. Schneider, J. Jeet, I. Amersdorffer, N. Arlt, F. Zacherl, R. Haas, D. Renisch, P. Mosel, P. Mosel, M. Kovacev, U. Morgner, C.E. Düllmann, E. Hudson, P.G. Thirolf, The concept of a laser-based conversion electron nuclear Mössbauer spectroscopy for a precise energy determination of 229mTh, Hyperfine Interactions 240, 23 (2019).

Abstracts and conference proceedings:

    1. L. v. d. Wense, B. Seiferle, Ch. Schneider, J. Jeet, I. Amersdorffer, N. Arlt, F. Zacherl, R. Haas, D. Renisch, Pa. Mosel, Ph. Mosel, M. Kovacev, U. Morgner, Ch.E. Düllmann, E.R. Hudson, and P.G. Thirolf, Towards a 229mTh energy determination with 40 μeV accuracy, Verhandl. DPG (VI), 54, A 18.4 (2019).
    2. B. Seiferle, L. v.d. Wense, I. Amersdorffer, P. G. Thirolf, Towards a precise energy determination of the 229Th nuclear isomer, Verhandl. DPG (VI), 54, A 18.7 (2019).
    3. J. Thielking, M.V. Okhapkin, P. Głowacki, D.-M. Meier, L. v. d. Wense, B. Seiferle, Ch. E. Düllmann, P.G. Thirolf, E. Peik, Laser spectroscopic characterization of the nuclear clock isomer 229mTh, Verhandl. DPG (VI), 54, A 35.16 (2019).
    4. O. Kaleja, B. Andjelic, O. Bezrodnova, K. Blaum, M. Block, S. Chenmarev, P. Chhetri,C. Droese, Ch. E. Düllmann, M. Eibach, J. Even, S. Eliseev, P. Filianin, F. Giacoppo,S. Götz, Y. Gusev, M. Gutiérrez, F. Herfurth, F.-P. Hessberger, N. Kalantar-Nayestanaki, J. Khuyagbaatar, J.J.W. van de Laar, M. Laatiaoui, S. Lohse,N. Martynova, E. Minaya-Ramirez, A. Mistry, T. Murböck, Y. Novikov, S. Raeder,D. Rodriguez, F. Schneider, L. Schweikhard, P. Thirolf, A. Yakushev, Penning-Trap Mass Spectrometry of the Heaviest Elements with SHIPTRAP, Verhandl. DPG (VI), 54, MS 8.1 (2019).
    5. F. Giacoppo, B. Andelic, K. Blaum, M. Block, P. Chhetri, C. Droese, Ch. E. Düllmann, M. Eibach, J. Even, S. Götz, N. Kalantar-Nayestanaki, O. Kaleja, M. Laatiaoui,A.K. Mistry, E. Minaya Ramirez, T. Murböck, S. Raeder, L. Schweikhard, P.G. Thirolf, Improved ion thermalization and preparation with the cryogenic buffer-gas stopping cell of SHIPTRAP, Verhandl. DPG (VI), 54, MS 8.2 (2019).
    6. B. Seiferle, I. Amersdorffer, L. v.d. Wense, P.G. Thirolf, Towards a direct energy determination of the 229Th nuclear isomer, Verhandl. DPG (VI), 54, HK 50.1 (2019).
    7. L. v.d. Wense, B. Seiferle, Ch. Schneider, J. Jeet, I. Amersdorffer, N. Arlt,F. Zacherl, R. Haas, D. Renisch, Pa. Mosel, Ph. Mosel, M. Kovacev, U. Morgner, Ch.E. Düllmann, E.R. Hudson, and P.G. Thirolf, Towards a 229mTh energy determination with 40 μV accuracy, Verhandl. DPG (VI), 54, HK 50.2 (2019).
    8. I. Amersdorffer, B. Seiferle, L. v.d. Wense, and P.G. Thirolf, Towards a nuclear clock: Neutralization of 229(m)Th ions in carbon foils, Verhandl. DPG (VI), 54, HK 54.40 (2019).

Books and Book Chapters

Book:

 

Book Chapter:

Thesis Works

PhD:                 

S. Meyer: On the Clinical Potential of Ion Computed Tomography with Different Detector Systems and Ion Species

B. Seiferle: Characterization of the 229Th Nuclear Clock Transmission

D. Haffa: Tailored Online Diagnostics for a Laser-driven Plasma Ion Source Prototype


Master Thesis (internal):

P. Wesp: Machine Learning Based Calibration for the Phase II Proton CT Scanner


Bachelor Thesis (internal):

J. Esslinger: Monte Carlo Impementation of a Realistic Beam Modes for a Small Animal Proton Radiography Setup

J. Müllner: Development of an experimental bench to characterize the sensitivity of ionoacoustic sensor technologies


Master Thesis (external):

M. Köhler: Nanoskopische Analyse der Chromatin-Organisation während der DNA-Doppelstrangbruchreparatur mittels STED-Mikroskopie (Universität der Bundeswehr München)

J. Schauer: Pre-experiment for fractionated proton-minibeam irradiation (Universität der Bundeswehr München)

H. von Zimmermann: Improved Reconstruction of Quantitative Letetium-177 Single Proton Emission Computed Tomography Images for Dosimetry (Klinik und Poliklinik für Nuklearmedizin des Klinikums der LMU)

 Bachelor Thesis (external):

B. Kahlert: Reconstruction of Auditory Signals from EES-Signals through Regression Analysis (Universität Erlangen-Nürnberg)

M. Kasparofsky: Untersuchungen von 2µm-und 3µm-Laserstrahlung für Laserlithotripsie (Laser-Forschungslabor des Klinikums der Universität München)

A. Rupp: Vermessung von Tumorzell-Sphäroiden mit Hilfe von entwickelten Plug-Ins (Klinikum der Universität München)

D. Lubotsky: Einschätzung der Nutzung von zwei Photopeaks zur Rekonstruktion in der 177Lu SPECT Bildgebung (Klinikum der LMU München)

V. Meiershofer: Bestimmung der Abbildungseigenschaften eines hochauflösenden PET/MR-Geräts (Klinikum der Universität München)

 




Zulassungsarbeit (State exam thesis):